標準號:BS EN 61558-2-9-2011
中文標準名稱:電力變壓器,電抗器,供電機組及其組合的安全性.Ⅲ類手用鎢絲燈變壓器和供電機組的詳細要求和試驗
英文標準名稱:Safety of transformers, reactors, power supply units and combinations thereof. Particular requirements and tests for transformers and power supply units for class III handlamps for tungsten filament lamps
標準類型:K41
發布日期:2011/3/30 12:00:00
實施日期:2011/3/30 12:00:00
中國標準分類號:K41
國際標準分類號:29.180
適用范圍:Replacement:This part of IEC 61558 deals with the safety of transformers for class III handlamps fortungsten filament lamps and power supply units incorporating transformers for class IIIhandlamps for tungsten filament lamps. Transformers incorporating electronic circuitsare also covered by this standard.NOTE 1 Safety includes electrical, thermal, mechanical and chemical aspects.Unless otherwise specified, from here onward, the term transformer covers transformers forclass III handlamps for tungsten filament lamps and power supply units incorporatingtransformers for class III handlamps for tungsten filament lamps.This part is applicable to stationary or portable single-phase air-cooled (natural or forced)independent or associated dry-type transformers. The windings may be encapsulated ornon-encapsulated.This standard is applicable to transformers and power supply (linear) with internaloperational frequencies not exceeding 500 Hz.This standard used in combination with Part 2-16 for switch mode power supply (SMPS)units is also applicable to power supplies with internal operational frequencies higher than500 Hz. Where the two requirements are in conflict, the most severe take precedence.The rated supply voltage does not exceed 1 000 V a.c., and the rated supply frequencyand the internal operational frequencies do not exceed 500 Hz.Transformers for class III handlamps for tungsten filament lamps have the followingadditional characteristics:– the no-load output voltage and the rated output voltage do not exceed 50 V a.c. or120 V ripple-free d.c.;– there is only a small difference between the no-load voltage and the rated outputvoltage.The rated output does not exceed:– 10 kVA.This part is not applicable to external circuits and their components intended to be connectedto the input terminals and output terminals of the transformers.Transformers covered by this part are used in applications where double or reinforcedinsulation between circuits is required by the installation rules or by the end productstandard.NOTE 2 Attention is drawn to the following:- for transformers intended to be used in vehicles, on board ships, and aircraft, additional requirements (fromother applicable standards, national rules, etc.) may be necessary;- measures to protect the enclosure and the components inside the enclosure against external influences suchas fungus, vermin, termites, solar-radiation, and icing should also be considered;- the different conditions for transportation, storage, and operation of the transformers should also beconsidered;- additional requirements in accordance with other appropriate standards and national rules may be applicable totransformers intended for use in special environments.NOTE 3 Future technological development of transformers may necessitate a need to increase the upper limit ofthe frequencies, until then this part may be used as a guidance document.
相關標準
《GB/T11032-20208.14,10.8.14》交流無間隙金屬氧化物避雷器
《GB/T11032-20208.13,10.8.13,11.8.13》交流無間隙金屬氧化物避雷器
《GB/T11032-20208.14,10.8.14》交流無間隙金屬氧化物避雷器
《GB/T11032-20208.21,10.8.21,11.8.21》交流無間隙金屬氧化物避雷器
《GB/T11032-202011.8.27》交流無間隙金屬氧化物避雷器
《GB/T11032-20208.11,10.8.11》交流無間隙金屬氧化物避雷器
《GB/T11032-20208.2,10.8.2,11.8.2,13.8.2》交流無間隙金屬氧化物避雷器
《GB/T11032-20208.12,10.8.12》交流無間隙金屬氧化物避雷器
《GB/T11032-20208.10,10.8.10,11.8.10》交流無間隙金屬氧化物避雷器
《GB/T11032-202011.8.28》交流無間隙金屬氧化物避雷器
百檢網專注于為第三方檢測機構以及中小微企業搭建互聯網+檢測電商服務平臺,是一個創新模式的檢驗檢測服務網站。百檢網致力于為企業提供便捷、高效的檢測服務,簡化檢測流程,提升檢測服務效率,利用互聯網+檢測電商,為客戶提供多樣化選擇,從根本上降低檢測成本提升時間效率,打破行業壁壘,打造出行業創新的檢測平臺。
百檢能給您帶來哪些改變?
1、檢測行業全覆蓋,滿足不同的檢測;
2、實驗室全覆蓋,就近分配本地化檢測;
3、工程師一對一服務,讓檢測更精準;
4、免費初檢,初檢不收取檢測費用;
5、自助下單 快遞免費上門取樣;
6、周期短,費用低,服務周到;
7、擁有CMA、CNAS、CAL等權威資質;
8、檢測報告權威有效、中國通用;