標準號:BS EN 60601-2-17-2004
中文標準名稱:醫療電氣設備.自動控制短距離放射治療后裝設備安全性的詳細要求
英文標準名稱:Medical electrical equipment. Particular requirements for the safety of automatically-controlled brachytherapy afterloading equipment
標準類型:C43
發布日期:2004/4/26 12:00:00
實施日期:2004/4/26 12:00:00
中國標準分類號:C43
國際標準分類號:11.040.50;13.280
適用范圍:Addition:
101 This Particular Standard specifies requirements for the safety of automatically-controlled EQUIPMENT for BRACHYTHERAPY of patients using AFTERLOADING techniques.
102 This Standard specifies requirements for automatically-controlled AFTERLOADING EQUIPMENT
- which contains and uses only beta, gamma, and NEUTRON-emitting SEALED RADIOACTIVE SOURCES,
- which automatically drives the sealed radioactive source(s) from a storage container to a treatment position inside the source applicator(s) and returns the source(s) to the storage container,
- which is designed for connection to a PATIENT, and
- with which movements of the RADIOACTIVE SOURCE(S) are carried out automatically by the EQUIPMENT according to a prescribed programme using a powered mechanism whose changes are controlled by the CONTROLLING TIMER(S) and TIMING DEVICES that are either PROGRAMMABLE ELECTRONIC SUB-SYSTEMS (PESS) (computer or microprocessors) or non-programmable systems.
103 This Standard specifies requirements for EQUIPMENT intended to be
- used under the supervision of QUALIFIED PERSONS;
- maintained at predetermined intervals;
- subject to regular checks by the user.
This Standard does not specify requirements for SEALED RADIOACTIVE SOURCES used with the EQUIPMENT. Such requirements are specified in other standards (see 6.8.3).
104 The requirements of this Standard are based on the assumptions that:
- a TREATMENT PLAN is available that prescribes appropriate values of the TREATMENT PARAMETERS, and
- the SOURCE STRENGTH(S) of the RADIOACTIVE SOURCE(S) used by the EQUIPMENT is (are) known.
This Standard includes requirements intended to ensure that the prescribed values of the TREATMENT PARAMETERS can be achieved by the EQUIPMENT, in particular that:
- the selected RADIOACTIVE SOURCE(S) is (are) positioned or moved within the SOURCE APPLICATOR in the selected configuration relative to the SOURCE APPLICATOR;
- IRRADIATION is performed by the selected RADIOACTIVE SOURCE configuration for the selected duration;
- IRRADIATION is performed by the EQUIPMENT without causing unnecessary risk to the OPERATOR or other persons in the immediate surroundings.
相關標準
《GB4824-2013cl.6,cl.7》工業、科學和醫療設備 射頻騷擾特性 限值和測量方法
《EN12015:20206.2.2》電磁兼容 電梯、自動扶梯和自動人行道的產品系列標準 發射
《GB/T17799.2-20038》電磁兼容 通用標準 工業環境中的抗擾度試驗
《GB/T24808-2009表2,3,4,5,6,7》電磁兼容 電梯、自動扶梯和自動人行道的產品系列標準 抗擾度
《EN12015:20146.4》電磁兼容 電梯、自動扶梯和自動人行道產品族標準 發射
《EN12015:20146.2,6.6》電磁兼容 電梯、自動扶梯和自動人行道產品族標準 發射
《IEC61000-6-4:2018Table2》電磁兼容 通用標準工業環境電磁發射通用要求
《GB17799.4-2012IEC61000-6-4:2006+A1:2010ENIEC61000-6-4:20199》電磁兼容 通用標準工業環境電磁發射通用要求
《GB/T24807-20096.2,6.6》電磁兼容 電梯、自動扶梯和自動人行道的產品系列標準 發射
《ENIEC61000-6-1:20192.1,3.1,4.1,5.1》電磁兼容 通用標準居住商業和輕工業環境中的抗擾度試驗
百檢網專注于為第三方檢測機構以及中小微企業搭建互聯網+檢測電商服務平臺,是一個創新模式的檢驗檢測服務網站。百檢網致力于為企業提供便捷、高效的檢測服務,簡化檢測流程,提升檢測服務效率,利用互聯網+檢測電商,為客戶提供多樣化選擇,從根本上降低檢測成本提升時間效率,打破行業壁壘,打造出行業創新的檢測平臺。
百檢能給您帶來哪些改變?
1、檢測行業全覆蓋,滿足不同的檢測;
2、實驗室全覆蓋,就近分配本地化檢測;
3、工程師一對一服務,讓檢測更精準;
4、免費初檢,初檢不收取檢測費用;
5、自助下單 快遞免費上門取樣;
6、周期短,費用低,服務周到;
7、擁有CMA、CNAS、CAL等權威資質;
8、檢測報告權威有效、中國通用;