標準號:IEC/TR 61000-3-13-2008
中文標準名稱:電磁兼容性(EMC).第3-13部分:限值.不平衡裝置對MV、HV和EHV動力系統的連接用排放限值的評估
英文標準名稱:Electromagnetic compatibility (EMC) - Part 3-13: Limits - Assessment of emission limits for the connection of unballanced installations to MV, HV and EHV power systems
標準類型:L06
發布日期:1999/12/31 12:00:00
實施日期:1999/12/31 12:00:00
中國標準分類號:L06
國際標準分類號:33.100.01
引用標準:IEC 60050-161
適用范圍:This part of IEC 61000 provides guidance on principles which can be used as the basis fordetermining the requirements for the connection of unbalanced installations (i.e. three-phaseinstallations causing voltage unbalance) to MV, HV and EHV public power systems (LVinstallations are covered in other IEC documents). For the purposes of this report, anunbalanced installation means a three-phase installation (which may be a load or a generator)that produces voltage unbalance on the system. The connection of single-phase installationsis not specifically addressed, as the connection of such installations is under the control of thesystem operator or owner. The general principles however may be adapted when consideringthe connection of single-phase installations. The primary objective is to provide guidance tosystem operators or owners on engineering practices, which will facilitate the provision ofadequate service quality for all connected customers. In addressing installations, thisdocument is not intended to replace equipment standards for emission limits.The report addresses the allocation of the capacity of the system to absorb disturbances. Itdoes not address how to mitigate disturbances, nor does it address how the capacity of thesystem can be increased.Since the guidelines outlined in this report are necessarily based on certain simplifyingassumptions, there is no guarantee that this approach will always provide the optimumsolution for all unbalanced load situations. The recommended approach should be used withflexibility and judgment as far as engineering is concerned, when applying the givenassessment procedures in full or in part.The system operator or owner is responsible for specifying requirements for the connection ofinstallations which may cause unbalance on the system. The disturbing installation is to beunderstood as the complete customer’s installation (i.e. including balanced and unbalancedparts).Problems related to unbalance fall into two basic categories.? Unbalanced installations that draw negative-sequence currents which produce negativesequencevoltages on the supply system. Examples of such installations include arcfurnaces and traction loads (typically connected to the public network at HV), and threephase installations where the individual loads are not balanced (typically connected at MVand LV). Negative-sequence voltage superimposed onto the terminal voltage of rotatingmachines can produce additional heat losses. Negative-sequence voltage can also causenon-characteristic harmonics (typically positive-sequence 3rd harmonic) to be produced bypower converters.? Unbalanced installations connected line-to-neutral can also draw zero-sequence currentswhich can be transferred or not into the supply system depending on the type ofconnection of the coupling transformer. The flow of zero-sequence currents in a groundedneutral system causes zero-sequence unbalance affecting line-to-neutral voltages. This isnot normally controlled by setting emission limits, but rather by system design andmaintenance. Ungrounded-neutral systems and phase-to-phase connected installationsare not, however, affected by this kind of voltage unbalance.
相關標準
百檢網專注于為第三方檢測機構以及中小微企業搭建互聯網+檢測電商服務平臺,是一個創新模式的檢驗檢測服務網站。百檢網致力于為企業提供便捷、高效的檢測服務,簡化檢測流程,提升檢測服務效率,利用互聯網+檢測電商,為客戶提供多樣化選擇,從根本上降低檢測成本提升時間效率,打破行業壁壘,打造出行業創新的檢測平臺。
百檢能給您帶來哪些改變?
1、檢測行業全覆蓋,滿足不同的檢測;
2、實驗室全覆蓋,就近分配本地化檢測;
3、工程師一對一服務,讓檢測更精準;
4、免費初檢,初檢不收取檢測費用;
5、自助下單 快遞免費上門取樣;
6、周期短,費用低,服務周到;
7、擁有CMA、CNAS、CAL等權威資質;
8、檢測報告權威有效、中國通用;