標準號:BS EN 61967-2-2005
中文標準名稱:集成電路.150kHz~1GHz電磁輻射的測量.第2部分:輻射釋放的測量.TEM輻射室和寬頻帶TEM輻射室法
英文標準名稱:Integrated circuits - Measurement of electromagnetic emissions, 150 kHz to 1 GHz - Part 2: Measurement of radiated emissions - TEM cell and wideband TEM cell method
標準類型:L56
發布日期:2006/1/23 12:00:00
實施日期:2006/1/23 12:00:00
中國標準分類號:L56
國際標準分類號:31.200;33.100.20
引用標準:IEC 60050-131-2002;IEC 60050-161-1990;IEC 61967-1
適用范圍:This test procedure defines a method for measuring the electromagnetic radiation from an integrated circuit (IC). The IC being evaluated is mounted on an IC test printed circuit board (PCB) that is clamped to a mating port (referred to as a wall port) cut in the top or bottom of a transverse electromagnetic (TEM) or wideband gigahertz TEM (GTEM) cell. The test board is not inside the cell, as in the conventional usage, but becomes a part of the cell wall. This method is applicable to any TEM or GTEM cell modified to incorporate the wall port; however, the measured radio frequency (RF) voltage will be affected by many factors. The primary factor affecting the measured RF voltage is the septum to IC test board (cell wall) spacing.This procedure was developed using a 1 GHz TEM cell with a septum to floor spacing of 45 mm and a GTEM cell with average septum to floor spacing of 45 mm over the port area.Other cells may not produce identical spectral output but may be used for comparative measurements, subject to their frequency and sensitivity limitations. A conversion factor may allow comparisons between data measured on TEM or GTEM cells with different septum to floor spacing.The IC test board controls the geometry and orientation of the operating IC relative to the cell and eliminates any connecting leads within the cell (these are on the backside of the board, which is outside the cell). For the TEM cell, one of the 50 Ω ports is terminated with a 50 Ω load. The other 50 Ω port for a TEM cell, or the single 50 Ω port for a GTEM cell, is connected to the input of a spectrum analyser or receiver that measures the RF emissions emanating from the integrated circuit and impressed onto the septum of the cell.
相關標準
《GBZ 125-2009》含密封源儀表的放射衛生防護要求 GBZ 125-2009
《GB/T 14056.1-2008》表面污染測定 第1部分:β發射體(Eβmax>0.15MeV)和α發射體 GB/T 14056.1-2008
《HJ/T 10.2-1996》輻射環境保護管理導則 電磁輻射監測儀器和方法 HJ/T 10.2-1996 第二章
《YD/T 3026-2016》通信基站電磁輻射管理技術要求 YD/T 3026-2016 9.3-9.5
《GB 31223-2014》氣象探測環境保護規范 天氣雷達站 GB 31223-2014 6.2
《HJ/T 10.2-1996》輻射環境保護管理導則 電磁輻射監測儀器和方法 HJ/T 10.2-1996 2
《YD/T 3026-2016》通信基站電磁輻射管理技術要求 YD/T 3026-2016 9.4-9.5
《HJ 681-2013》交流輸變電工程電磁環境監測方法 HJ 681-2013 4.4
《HJ/T 10.2-1996》輻射環境保護管理導則 電磁輻射監測儀器和方法 HJ/T 10.2-1996 第二章
《YD/T 2380-2011》人體暴露于RFID設備電磁場的評估方法 YD/T 2380-2011 3、4、5、6、7
百檢網專注于為第三方檢測機構以及中小微企業搭建互聯網+檢測電商服務平臺,是一個創新模式的檢驗檢測服務網站。百檢網致力于為企業提供便捷、高效的檢測服務,簡化檢測流程,提升檢測服務效率,利用互聯網+檢測電商,為客戶提供多樣化選擇,從根本上降低檢測成本提升時間效率,打破行業壁壘,打造出行業創新的檢測平臺。
百檢能給您帶來哪些改變?
1、檢測行業全覆蓋,滿足不同的檢測;
2、實驗室全覆蓋,就近分配本地化檢測;
3、工程師一對一服務,讓檢測更精準;
4、免費初檢,初檢不收取檢測費用;
5、自助下單 快遞免費上門取樣;
6、周期短,費用低,服務周到;
7、擁有CMA、CNAS、CAL等權威資質;
8、檢測報告權威有效、中國通用;