標(biāo)準(zhǔn)號(hào):ANSI/ASTM D4473-2001
中文標(biāo)準(zhǔn)名稱(chēng):采用動(dòng)態(tài)機(jī)械特性測(cè)量熱固樹(shù)脂彎曲特性
英文標(biāo)準(zhǔn)名稱(chēng):Measuring the Cure Behavior of Thermosetting Resins Using Dynamic Mechanical Properties (08.03)
標(biāo)準(zhǔn)類(lèi)型:G31
發(fā)布日期:1999/12/31 12:00:00
實(shí)施日期:2001/9/25 12:00:00
中國(guó)標(biāo)準(zhǔn)分類(lèi)號(hào):G31
國(guó)際標(biāo)準(zhǔn)分類(lèi)號(hào):83.080.10
適用范圍:This practice covers the use of dynamic-mechanical-oscillation instrumentation for gathering and reporting the thermal advancement of cure behavior of thermosetting resin. It may be used for determining the cure properties of unsupported resins and resins supported on substrates and subjected to various oscillatory deformations. These deformations may be in shear or the dynamic compression of supported resins using a dynamic mechanical instrument. This practice is intended to provide means for determining the cure behavior of supported and unsupported thermosetting resins over a range of temperatures by free vibration and resonant and nonresonant forced-vibration techniques, in accordance with Practice D4065. Plots of modulus, cure behavior, tan delta, and damping index as a function of time/temperature are indicative of the thermal advancement or cure characteristics of a resin. This practice is valid for a wide range of frequencies, typically from 0.01 to 100 Hz. However, it is strongly recommended that low-frequency test conditions, generally below 1.5 Hz, will generate more definitive cure-behavior information. This practice is intended for resin/substrate composites that have an uncured effective elastic modulus in shear greater than 0.5 MPa. Apparent discrepancies may arise in results obtained under differing experimental conditions. These apparent differences from results observed in another study can usually be reconciled, without changing the observed data, by reporting in full (as described in this practice) the conditions under which the data were obtained. Due to possible instrumentation compliance, especially in the compressive mode, the data generated may indicate relative and not necessarily absolute property values. The values stated in SI units are to be regarded as the standard. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific precautionary statements are given in Note 5. Note 1-There is no similar or equivalent ISO standard.
相關(guān)標(biāo)準(zhǔn)
《GB/T21794-2008》化學(xué)品 體外哺乳動(dòng)物細(xì)胞染色體畸變?cè)囼?yàn)方法
《二、(二)、10》衛(wèi)生部 化學(xué)品毒性鑒定技術(shù)規(guī)范 (2005年)
《GB/T21753-2008》化學(xué)品 21天/28天重復(fù)劑量經(jīng)皮毒性試驗(yàn)方法
《418有機(jī)磷化合物急性染毒的遲發(fā)性神經(jīng)毒性試驗(yàn)》化學(xué)品測(cè)試方法 健康效應(yīng)卷(第二版)
《GB/T21750-2008》化學(xué)品 毒物代謝動(dòng)力學(xué)試驗(yàn)方法
《二、(三)、2》衛(wèi)生部 化學(xué)品毒性鑒定技術(shù)規(guī)范 (2005年)
《405急性眼刺激性/腐蝕性試驗(yàn)》化學(xué)品測(cè)試方法 健康效應(yīng)卷(第二版)
《GB/T21752-2008》化學(xué)品 嚙齒動(dòng)物28天重復(fù)劑量經(jīng)口毒性試驗(yàn)方法
《二、(三)、1》衛(wèi)生部 化學(xué)品毒性鑒定技術(shù)規(guī)范 (2005年)
《GB/T21773-2008》化學(xué)品 體內(nèi)哺乳動(dòng)物紅細(xì)胞微核試驗(yàn)方法
百檢網(wǎng)專(zhuān)注于為第三方檢測(cè)機(jī)構(gòu)以及中小微企業(yè)搭建互聯(lián)網(wǎng)+檢測(cè)電商服務(wù)平臺(tái),是一個(gè)創(chuàng)新模式的檢驗(yàn)檢測(cè)服務(wù)網(wǎng)站。百檢網(wǎng)致力于為企業(yè)提供便捷、高效的檢測(cè)服務(wù),簡(jiǎn)化檢測(cè)流程,提升檢測(cè)服務(wù)效率,利用互聯(lián)網(wǎng)+檢測(cè)電商,為客戶(hù)提供多樣化選擇,從根本上降低檢測(cè)成本提升時(shí)間效率,打破行業(yè)壁壘,打造出行業(yè)創(chuàng)新的檢測(cè)平臺(tái)。
百檢能給您帶來(lái)哪些改變?
1、檢測(cè)行業(yè)全覆蓋,滿(mǎn)足不同的檢測(cè);
2、實(shí)驗(yàn)室全覆蓋,就近分配本地化檢測(cè);
3、工程師一對(duì)一服務(wù),讓檢測(cè)更精準(zhǔn);
4、免費(fèi)初檢,初檢不收取檢測(cè)費(fèi)用;
5、自助下單 快遞免費(fèi)上門(mén)取樣;
6、周期短,費(fèi)用低,服務(wù)周到;
7、擁有CMA、CNAS、CAL等權(quán)威資質(zhì);
8、檢測(cè)報(bào)告權(quán)威有效、中國(guó)通用;