標(biāo)準(zhǔn)號:ISO 16063-15-2006
中文標(biāo)準(zhǔn)名稱:振動和沖擊傳感器的校準(zhǔn)方法.第15部分:用激光干涉法的初級角振動校準(zhǔn)
英文標(biāo)準(zhǔn)名稱:Methods for the calibration of vibration and shock transducers - Part 15: Primary angular vibration calibration by laser interferometry
標(biāo)準(zhǔn)類型:L15
發(fā)布日期:1999/12/31 12:00:00
實(shí)施日期:1999/12/31 12:00:00
中國標(biāo)準(zhǔn)分類號:L15
國際標(biāo)準(zhǔn)分類號:17.160
適用范圍:This part of ISO 16063 specifies the instrumentation and procedures used for primary angular vibrationcalibration of angular transducers, i.e. angular accelerometers, angular velocity transducers and rotationalangle transducers (with or without amplifier) to obtain the magnitude and the phase shift of the complexsensitivity by steady-state sinusoidal vibration and laser interferometry. The methods specified in this part ofISO 16063 are applicable to measuring instruments (rotational laser vibrometers in particular) and to angulartransducers as defined in ISO 2041 for the quantities of rotational angle, angular velocity and angularacceleration.It is applicable to a frequency range from 1 Hz to 1,6 kHz and a dynamic range (amplitude) from 0,1 rad/s2 to1 000 rad/s2 (frequency-dependent).These ranges are covered with the uncertainty of measurement specified in Clause 3. Calibration frequencieslower than 1 Hz (e.g. 0,4 Hz, which is a reference frequency used in other International Standards) andangular acceleration amplitudes smaller than 0,1 rad/s2 can be achieved using method 3A or method 3Bspecified in this part of ISO 16063, in conjunction with an appropriate low-frequency angular vibrationgenerator.Method 1A (cf. Clause 8: fringe-counting, interferometer type A) and method 1B (cf. Clause 8: fringe-counting,interferometer type B) are applicable to the calibration of the magnitude of complex sensitivity in the frequencyrange of 1 Hz to 800 Hz and under special conditions, at higher frequencies. Method 2A (cf. Clause 9:minimum-point method, interferometer type A) and method 2B (cf. Clause 9: minimum-point method,interferometer type B) can be used for sensitivity magnitude calibration in the frequency range of 800 Hz to1,6 kHz. Method 3A (cf. Clause 10: sine-approximation method, interferometer type A) and method 3B(cf. Clause 10: sine-approximation method, interferometer type B) can be used for magnitude of sensitivityand phase calibration in the frequency range of 1 Hz to 1,6 kHz. Methods 1A, 1B and 3A, 3B provide forcalibrations at fixed angular acceleration amplitudes at various frequencies. Methods 2A and 2B requirecalibrations at fixed rotational angle amplitudes (angular velocity amplitude and angular accelerationamplitude vary with frequency).
相關(guān)標(biāo)準(zhǔn)
《QB/T 2934-2018》草編制品 QB/T 2934-2018
《GB/T 21294-2014》服裝理化性能的檢驗(yàn)方法 GB/T 21294-2014
《GB/T 31900-2015》機(jī)織兒童服裝? GB/T 31900-2015
《DB41/T?263-2014》絮用纖維制品 棉胎? DB41/T?263-2014
《GB 18383-2007》絮用纖維制品通用技術(shù)要求 GB 18383-2007
《GB/T 14576-2009》紡織品 色牢度試驗(yàn) 耐光、汗復(fù)合色牢度 GB/T 14576-2009
《GB/T 31888-2015》中小學(xué)生校服 GB/T 31888-2015
《FZ/T 01057-2007》紡織纖維鑒別試驗(yàn)方法(所有部分) FZ/T 01057-2007
《GB/T 21294-2014》服裝理化性能的檢驗(yàn)方法 GB/T 21294-2014
《FZ/T 81018-2014》機(jī)織人造革服裝 FZ/T 81018-2014
百檢網(wǎng)專注于為第三方檢測機(jī)構(gòu)以及中小微企業(yè)搭建互聯(lián)網(wǎng)+檢測電商服務(wù)平臺,是一個創(chuàng)新模式的檢驗(yàn)檢測服務(wù)網(wǎng)站。百檢網(wǎng)致力于為企業(yè)提供便捷、高效的檢測服務(wù),簡化檢測流程,提升檢測服務(wù)效率,利用互聯(lián)網(wǎng)+檢測電商,為客戶提供多樣化選擇,從根本上降低檢測成本提升時間效率,打破行業(yè)壁壘,打造出行業(yè)創(chuàng)新的檢測平臺。
百檢能給您帶來哪些改變?
1、檢測行業(yè)全覆蓋,滿足不同的檢測;
2、實(shí)驗(yàn)室全覆蓋,就近分配本地化檢測;
3、工程師一對一服務(wù),讓檢測更精準(zhǔn);
4、免費(fèi)初檢,初檢不收取檢測費(fèi)用;
5、自助下單 快遞免費(fèi)上門取樣;
6、周期短,費(fèi)用低,服務(wù)周到;
7、擁有CMA、CNAS、CAL等權(quán)威資質(zhì);
8、檢測報(bào)告權(quán)威有效、中國通用;