標準號:IEC 60976-2007
中文標準名稱:醫用電氣設備.醫用電子加速器.功能特性
英文標準名稱:Medical electrical equipment - Medical electron accelerators - Functional performance characteristics
標準類型:C37
發布日期:1999/12/31 12:00:00
實施日期:1999/12/31 12:00:00
中國標準分類號:C37
國際標準分類號:11.040.50;13.280
適用范圍:This International Standard applies to medical ELECTRON ACCELERATORS when used, fortherapy purposes, in human medical practice.This standard applies to medical ELECTRON ACCELERATORS which deliver a RADIATION BEAM ofeither X-RADIATION or ELECTRON RADIATION with NOMINAL ENERGIES in the range 1 MeV to 50 MeVat maximum ABSORBED DOSE RATES between 0,001 Gy s–1 and 1 Gy s–1 at 1 m from theRADIATION SOURCE and at NORMAL TREATMENT DISTANCES between 50 cm and 200 cm from theRADIATION SOURCE.The present standard describes measurements and test procedures to be performed by theMANUFACTURER at the design and construction stage of a medical ELECTRON ACCELERATOR butdoes not specify ACCEPTANCE TESTS to be performed after installation at the purchaser's site.The accompanying report, IEC 60977, however, does suggest that many of the testprocedures are appropriate for ACCEPTANCE TESTS.The measurement conditions described in the present standard differ from those previously inuse. This applies particularly to the PHANTOM position for measurements and themeasurement of distances from the ISOCENTRE. These new conditions should be substitutedfor and not be added to previous methods.This standard specifies test procedures for the determination and disclosure of functionalperformance characteristics, knowledge of which is deemed necessary for proper applicationand use of a medical ELECTRON ACCELERATOR and which are to be declared in theACCOMPANYING DOCUMENTS together with the greatest deviation or variation to be expectedunder specific conditions in NORMAL USE. A format for presentation of functional performancevalues is given in Annex A.It is recognized that inaccuracies in the test methods must be allowed for when assessingperformance. However, it was not felt to be advisable to combine the errors into an overallperformance tolerance but to keep them separate in the expectation that more accurate testmethods will be evolved.It is not intended that this standard should in any way inhibit the future development of newdesigns of equipment which may have operating modes and parameters different from thosedescribed herein, provided that such equipment achieves equivalent levels of performance forthe TREATMENT of PATIENTS.Except where otherwise stated this standard assumes that the medical ELECTRONACCELERATORS have an ISOCENTRIC GANTRY. Where the equipment is non-isocentric, thedescription of performance and test methods may need to be suitably adapted.NOTE A statement of compliance with this standard does not necessarily imply that these tests will be or have been applied as TYPE TESTS or as individual tests.
相關標準
《GB/T 5169.16-2008》電工電子產品著火危險試驗 第16部分:試驗火焰 50W 水平與垂直火焰試驗方法 GB/T 5169.16-2008
《GB/T 19042.1-2003》醫用成像部門的評價及例行試驗 第3-1 部分:X射線攝影和透視系統用X射線 設備成像性能驗收試驗 GB/T 19042.1-2003 5.2
《GB/T 19042.1-2003》醫用成像部門的評價及例行試驗 第3-1 部分:X射線攝影和透視系統用X射線 設備成像性能驗收試驗 GB/T 19042.1-2003 7.2
《GB/T 19042.1-2003》醫用成像部門的評價及例行試驗 第3-1 部分:X射線攝影和透視系統用X射線 設備成像性能驗收試驗 GB/T 19042.1-2003 5.4
《GB/T 19042.1-2003》醫用成像部門的評價及例行試驗 第3-1 部分:X射線攝影和透視系統用X射線 設備成像性能驗收試驗 GB/T 19042.1-2003 5.6
《GB/T 19042.1-2003》醫用成像部門的評價及例行試驗 第3-1 部分:X射線攝影和透視系統用X射線 設備成像性能驗收試驗 GB/T 19042.1-2003 6.9
《GB/T 19042.1-2003》醫用成像部門的評價及例行試驗 第3-1 部分:X射線攝影和透視系統用X射線 設備成像性能驗收試驗 GB/T 19042.1-2003 5.5
《YY0636.1-2008
ISO 10079-1:2015
EN ISO 10079-1: 2015
ISO 10079-1:2015/Amd.1:2018(E)》醫用吸引設備 第1部分:電動吸引設備 YY0636.1-2008
ISO 10079-1:2015
EN ISO 10079-1: 2015
ISO 10079-1:2015/Amd.1:2018(E)
《GB 17589-2011》X射線計算機斷層攝影裝置質量保證檢測規范 GB 17589-2011
《YY0503-2016》環氧乙烷滅菌器 YY0503-2016 5.3.1.1
百檢網專注于為第三方檢測機構以及中小微企業搭建互聯網+檢測電商服務平臺,是一個創新模式的檢驗檢測服務網站。百檢網致力于為企業提供便捷、高效的檢測服務,簡化檢測流程,提升檢測服務效率,利用互聯網+檢測電商,為客戶提供多樣化選擇,從根本上降低檢測成本提升時間效率,打破行業壁壘,打造出行業創新的檢測平臺。
百檢能給您帶來哪些改變?
1、檢測行業全覆蓋,滿足不同的檢測;
2、實驗室全覆蓋,就近分配本地化檢測;
3、工程師一對一服務,讓檢測更精準;
4、免費初檢,初檢不收取檢測費用;
5、自助下單 快遞免費上門取樣;
6、周期短,費用低,服務周到;
7、擁有CMA、CNAS、CAL等權威資質;
8、檢測報告權威有效、中國通用;