標準號:SAE J 2698-2008
中文標準名稱:卡車和汽車用初始單項標稱交流電壓為120VAC的布線組件設計
英文標準名稱:Primary Single Phase Nominal 120 VAC Wiring Distribution Assembly Design Truck and Bus
標準類型:T36
發布日期:2008/1/15 12:00:00
實施日期:1999/12/31 12:00:00
中國標準分類號:T36
國際標準分類號:43.040.10
引用標準:ANSI/NFPA 70-2008;SAE J 223/2;SAE J 447-1995;SAE J 560-2004;SAE J 1128-2005;SAE J 1455-2006;SAE J 1654-2004;SAE J 1742-2005;SAE J 1980-2001;UL 20-2000;UL 50-2007;UL 62-2006;UL 83-2003;UL 310-2003;UL 467-2007;UL 489-2002;UL 498-2001;UL 514A-2004;UL 514B-20
適用范圍:This SAE Recommended Practice covers the design and application of primary on-board wiring distribution system harnessing for surface vehicles. This document is intended for single phase nominal 120 VAC circuits that provide power to truck sleeper cab hotel loads so that they may operate with the main propulsion engine turned off. The power supply comes from alternative sources such as land-based grid power, DC-AC inverters and auxiliary power generators. The circuits may also provide power to improve vehicle performance through charging batteries or operating cold-weather starting aids. This document is not intended to provide guidance for electric or hybrid electric vehicle wiring circuits. Refer to SAE J1673 for high voltage automotive wiring assembly design. It is understood that drivers may choose to operate 120 VAC devices with the truck moving or at rest. For example, a passenger may operate the microwave or watch television and need to operate an inverter. The environment that these devices are operated in can also vary with exterior ambient temperature extremes. Exposure to oil and vibration are other elements that typical household 120 VAC wiring would not normally be exposed to; therefore, the construction of this power distribution is made more robust for a mobile trucking environment. Driver interaction with the 120 VAC power through use of appliances or connection of cord sets requires special attention to safety aspects dictated in regulatory standards from Nationally Recognized Testing Laboratories (NRTLs) approved labs like Underwriter's Laboratories (UL), Canadian Standards Association (CSA) or from the National Electric Code (NEC) that are not common practice with typical 12 VDC vehicle wiring. This recommended practice supports that all electrical materials, devices, components, appliances, fittings and equipment shall be Listed, Labeled or Certified to UL and CSA standards and shall be connected in an approved manner when installed. Detailed requirements are listed hereafter.
相關標準
《JB/T5415-2013》微型離心泵
《JB/T10303-2020》工頻柴油發電機組技術條件
《JB/T10303-2020》工頻柴油發電機組技術條件
《JB/T10303-2020》工頻柴油發電機組技術條件
《JB/T10303-2020》工頻柴油發電機組技術條件
《JB/T10303-2020》工頻柴油發電機組技術條件
《JB/T10303-2020》工頻柴油發電機組技術條件
《JB/T10303-2020》工頻柴油發電機組技術條件
《JB/T10303-2020》工頻柴油發電機組技術條件
《JB/T10303-2020》工頻柴油發電機組技術條件
百檢網專注于為第三方檢測機構以及中小微企業搭建互聯網+檢測電商服務平臺,是一個創新模式的檢驗檢測服務網站。百檢網致力于為企業提供便捷、高效的檢測服務,簡化檢測流程,提升檢測服務效率,利用互聯網+檢測電商,為客戶提供多樣化選擇,從根本上降低檢測成本提升時間效率,打破行業壁壘,打造出行業創新的檢測平臺。
百檢能給您帶來哪些改變?
1、檢測行業全覆蓋,滿足不同的檢測;
2、實驗室全覆蓋,就近分配本地化檢測;
3、工程師一對一服務,讓檢測更精準;
4、免費初檢,初檢不收取檢測費用;
5、自助下單 快遞免費上門取樣;
6、周期短,費用低,服務周到;
7、擁有CMA、CNAS、CAL等權威資質;
8、檢測報告權威有效、中國通用;