標(biāo)準(zhǔn)號:IS 2952 Pt.2-1975
發(fā)布日期:1975/12/1 12:00:00
實施日期:1999/12/31 12:00:00
適用范圍:1.1 This standard (Part II) specifies the profile, sizes and materials for cons-truction of orifice plates and nozzles and outlines procedure for measurement of flow of gases under steady conditions up to a Mach number of 0.5 at the orifice.1.2 Details of connections between primary and secondary elements are proposed to be covered in a separate standard. Further, this standard does not cover the measurement of steam, wet gases or mixtures.1.3 This standard also provides the data on discharge coefficients for use in computing the rate of flow through these devices of specified profile when direct calibrations have not been made on them and provides an example (see Appendix A) for computation of flow using the equations recommended. The discharge coefficients are applicable to the following conditions:a) Orifice Plates1) Corner tapsi) Upstream Reynolds number between 5×103 and 107, ii) Pipe diameter between 50 and 1 000 mm,iii) Diameter ratio between 0.22 and 0.8, andiv) Pressure ratio greater than 0.75.2) Vena contracta tapsi) Upstream Reynolds number between 6×103 and 107,ii) Pipe diameter between 50 and 760 mm, iii) Diameter ratio between 0.1 and 0.8, and iv) Pressure ratio greater than 0.75.3) Flange tapsi) Upstream Reynolds number between 8 ×103 and 107, ii) Pipe diameter between 50 and 760 mm, iii) Diameter ratio between 0.1 and 0.75, and iv) Pressure ratio greater than 0.75.b) Nozzles1) ISA 1932 nozzlesi) Upstream Reynolds number between 2×104 and 1.17 × 106, ii) Pipe diameter between 50 and 1 000 mm, iii) Diameter ratio between 0.316 and 0.8, and iv) Pressure ratio greater than 0.75.2) Long radius nozzlesi) Upstream Reynolds number between 6×103 and 107, ii) Pipe diameter between 50 and 200 mm, iii) Diameter ratio between 0.2 and 0.8, and iv) Pressure ratio greater than 0.75.1.4 Individual calibrations should be made when the profile (see 7 and 8) and installation conditions (see 5.3) differ from this standard.
相關(guān)標(biāo)準(zhǔn)
《GB/T10813.1-20156.8.1》日用青瓷器
《GB/T10813.1-20156.1》日用青瓷器
《GB/T10813.4-20156.2》青瓷器 第4部分 青瓷包裝容器
《GB/T10813.1-20156.8》日用青瓷器
《GB/T10813.1-20156.2》日用青瓷器
《GB/T10813.1-20156.3》日用青瓷器
《GB/T10813.4-20156.2》青瓷器 第4部分 青瓷包裝容器
《GB/T10813.4-20156.4》青瓷器 第4部分 青瓷包裝容器
《GB/T10813.1-20156.8.2》日用青瓷器
《GB/T10813.4-20156.1》青瓷器 第4部分 青瓷包裝容器
百檢網(wǎng)專注于為第三方檢測機構(gòu)以及中小微企業(yè)搭建互聯(lián)網(wǎng)+檢測電商服務(wù)平臺,是一個創(chuàng)新模式的檢驗檢測服務(wù)網(wǎng)站。百檢網(wǎng)致力于為企業(yè)提供便捷、高效的檢測服務(wù),簡化檢測流程,提升檢測服務(wù)效率,利用互聯(lián)網(wǎng)+檢測電商,為客戶提供多樣化選擇,從根本上降低檢測成本提升時間效率,打破行業(yè)壁壘,打造出行業(yè)創(chuàng)新的檢測平臺。
百檢能給您帶來哪些改變?
1、檢測行業(yè)全覆蓋,滿足不同的檢測;
2、實驗室全覆蓋,就近分配本地化檢測;
3、工程師一對一服務(wù),讓檢測更精準(zhǔn);
4、免費初檢,初檢不收取檢測費用;
5、自助下單 快遞免費上門取樣;
6、周期短,費用低,服務(wù)周到;
7、擁有CMA、CNAS、CAL等權(quán)威資質(zhì);
8、檢測報告權(quán)威有效、中國通用;