標(biāo)準(zhǔn)號:BS ISO 9370-1997
中文標(biāo)準(zhǔn)名稱:塑料制品.風(fēng)化試驗輻射暴露度的儀器測定.一般指南和基本試驗方法
英文標(biāo)準(zhǔn)名稱:Plastics - Instrumental determination of radiant exposure in weathering tests - General guidance and basic test method
標(biāo)準(zhǔn)類型:G31
發(fā)布日期:1997/12/15 12:00:00
實施日期:1997/12/15 12:00:00
中國標(biāo)準(zhǔn)分類號:G31
國際標(biāo)準(zhǔn)分類號:83.080.01
適用范圍:1 This International Standard specifies methods for the instrumental measurement of irradiance on a planar surface. This includes both natural and simulated natural exposure testing.
2 Instrumental techniques include the continuous measurement of total solar and spectral solar irradiance (with emphasis on the ultraviolet wavelength region), and the
accumulation (or integration) of instantaneous data to provide a total radiant exposure (dosage).
3 Exposure in apparatus using artificial light sources sometimes requires measurement of irradiance and radiant exposure at specified wavelengths in order to monitor and, if required, control the irradiance on a planar surface and/or to define quantitatively the exposure stages of an exposed specimen. Typically, measurements of radiation in the 290 nm to 400 nm band, or narrow-band measurements with centre wavelengths at, for example, 340 nm or 420 nm, are required. However, in contrast to natural exposure conditions, radiation of wavelengths shorter than 300 nm is present in most light sources used in laboratory accelerated tests, and is known to cause rapid degradation in many polymers. In addition, radiation of longer wavelengths can be very important in product degradation such as colour fade. Therefore, it may be very useful to monitor short-wavelength radiation of less than 300 nm and long-wavelength radiation at wavelengths greater than 400 nm.
4 This International Standard does not specify procedures using blue wool standards, chemical actinometry, monochromators or polymeric and other film dosimetry.
NOTE 1 This should not be construed to imply that such techniques are
undesirable. Efforts are under way in several countries to develop polymeric dosimeters for this purpose.
NOTE 2 Monochromators are usually used in spectroradiometric systems where
high-resolution precision scanning of a passband is required.
5 The total solar and solar ultraviolet radiation measuring instruments described in this International Standard can be used in the following exposure tests:
a) Natural exposure tests
Measurement of total solar and solar ultraviolet radiation using the instruments and procedures specified in this International Standard will improve the comparability of exposure tests conducted at different times in a single location. It may also improve the comparability of results obtained in different locations with similar climates.
However, comparison of results from exposures in different locations must also consider the effects of temperature, moisture and other climatic factors on the type and rate of product degradation as well as the level of solar radiation.
NOTE 3 While the instrument performance data described in tables 1 and 2 may be considered as a specification, especially for instruments that measure total solar radiation, instruments currently available for measurement of solar ultraviolet radiation may not meet all of the performance features listed.
b) Comparison between natural exposure and laboratory accelerated tests Measurements of ultraviolet and/or visible radiation using the instruments and procedures specified in this International Standard may aid in comparing results from artificial accelerated tests with those from natural exposure. When this is done, comparison should be made in several passbands. Comparing the radiation in a short-wavelength UV passband is necessary to gauge the relative severity of the exposure and to estimate the risk that the accelerated test might produce degradation reactions that would not occur in a natural exposure. The intensity and spectral distribution of the radiation used in accelerated tests is only one factor in determining the comparability of results obtained in natural exposures. One must also consider temperature, moisture and other climatic factors (notably pollution effects) when making these comparisons. Because of differences between a material's response to increased radiation levels and
相關(guān)標(biāo)準(zhǔn)
《YBB00282003-2015》藥用鈉鈣玻璃管
《YBB00372004-2015》砷、銻、鉛、鎘浸出量測定法
《YBB00032005-2015》鈉鈣玻璃輸液瓶
《YBB00232003-2015》三氧化二硼測定法_
《YBB00122004-2015》筆式注射器用硼硅玻璃珠
《YBB00302002-2015》低硼硅玻璃管制注射瓶
《YBB00122004-2015》筆式注射器用硼硅玻璃珠
《YBB00202003-2015/
YBB00212003-2015》平均線熱膨脹系數(shù)測定法
《YBB00282003-2015》藥用鈉鈣玻璃管
《YBB00252003-2015》玻璃顆粒在121℃耐水性測定法和分級
百檢網(wǎng)專注于為第三方檢測機(jī)構(gòu)以及中小微企業(yè)搭建互聯(lián)網(wǎng)+檢測電商服務(wù)平臺,是一個創(chuàng)新模式的檢驗檢測服務(wù)網(wǎng)站。百檢網(wǎng)致力于為企業(yè)提供便捷、高效的檢測服務(wù),簡化檢測流程,提升檢測服務(wù)效率,利用互聯(lián)網(wǎng)+檢測電商,為客戶提供多樣化選擇,從根本上降低檢測成本提升時間效率,打破行業(yè)壁壘,打造出行業(yè)創(chuàng)新的檢測平臺。
百檢能給您帶來哪些改變?
1、檢測行業(yè)全覆蓋,滿足不同的檢測;
2、實驗室全覆蓋,就近分配本地化檢測;
3、工程師一對一服務(wù),讓檢測更精準(zhǔn);
4、免費初檢,初檢不收取檢測費用;
5、自助下單 快遞免費上門取樣;
6、周期短,費用低,服務(wù)周到;
7、擁有CMA、CNAS、CAL等權(quán)威資質(zhì);
8、檢測報告權(quán)威有效、中國通用;