標準號:IEC 61290-11-1-2008
中文標準名稱:光學放大器.試驗方法.第11-1部分:偏振模式分散參數.瓊斯矩陣特征分析法(JME)
英文標準名稱:Optical amplifier - Test methods - Part 11-1: Polarization mode dispersion parameter - Jones matrix eigenanalysis (JME)
標準類型:M33
發布日期:1999/12/31 12:00:00
實施日期:1999/12/31 12:00:00
中國標準分類號:M33
國際標準分類號:33.180.30
引用標準:IEC/TR 61282-9;IEC/TR 61292-5
適用范圍:This part of IEC 61290 applies to all commercially available optical amplifiers (OAs), includingoptical fibre amplifiers (OFAs) using active fibres, semiconductor optical amplifiers (SOAs),and planar waveguide optical amplifiers (PWOAs).Polarization-mode dispersion (PMD) causes an optical pulse to spread in the time domain.This dispersion could impair the performance of a telecommunications system. The effect canbe related to differential group velocity and corresponding arrival times of differentpolarization components of the signal. For a narrowband source, the effect can be related toa differential group delay (DGD) between pairs of orthogonally polarized principal statesof polarization (PSP). Other information about PMD may be found in IEC 61282-9 in generaland in IEC 61292-5 on OAs in particular.This test method describes a procedure for measuring the PMD of OAs. The measurementresult is obtained from the measurement of the normalized Stokes parameters at two closelyspaced wavelengths.The test method described herein requires a polarized signal at the input of the polarimeterwith a degree of polarization (DOP) of at least 25 %. Although the test source is highlypolarized, the DOP at the output of the OA is reduced by amplified spontaneous emission(ASE). Annex A analyses the impact of ASE on the DOP. In order to assure an accuratemeasurement, the DOP is measured as part of the measurement procedure.The method described herein has been shown to be immune to polarization-dependent gain(PDG) and polarization dependent loss (PDL) up to approximately 1 dB.Although the Jones matrix eigenanalysis (JME) test method is in principle also applicable tounpumped (that is, unpowered) OAs, the JME technique in this standard applies to pumped(that is, powered) OAs only.
相關標準
《GB/T30157-2013》紡織品 總鉛和總鎘含量的測定
《GB/T17593.2-2007》紡織品 重金屬的測定 第2部分:電感耦合等離子體原子發射光譜法
《EN16128:2011》與皮膚長時間緊密接觸的眼鏡架和太陽鏡的組件的鎳釋放量參考試驗方法
《EN1811-2011+A1:2015》直接長期接觸皮膚的產品中鎳釋放的測試方法
《GB/T17593.4-2006》紡織品 重金屬的測定 第4部分 砷、汞原子熒光分光光度法
《GB/T20386-2006》紡織品 鄰苯基苯酚的測定
《EN12472:2005》涂層部件鎳釋放量的檢測用磨損和腐蝕的模擬方法
《GB/T17593.3-2006》紡織品 重金屬的測定 第3部分六價鉻 分光光度法
《GB/T18412.2-2006》紡織品 農藥殘留量的測定 第2部分:有機氯農藥
《GB/T20387-2006》紡織品 多氯聯苯的測定
百檢網專注于為第三方檢測機構以及中小微企業搭建互聯網+檢測電商服務平臺,是一個創新模式的檢驗檢測服務網站。百檢網致力于為企業提供便捷、高效的檢測服務,簡化檢測流程,提升檢測服務效率,利用互聯網+檢測電商,為客戶提供多樣化選擇,從根本上降低檢測成本提升時間效率,打破行業壁壘,打造出行業創新的檢測平臺。
百檢能給您帶來哪些改變?
1、檢測行業全覆蓋,滿足不同的檢測;
2、實驗室全覆蓋,就近分配本地化檢測;
3、工程師一對一服務,讓檢測更精準;
4、免費初檢,初檢不收取檢測費用;
5、自助下單 快遞免費上門取樣;
6、周期短,費用低,服務周到;
7、擁有CMA、CNAS、CAL等權威資質;
8、檢測報告權威有效、中國通用;