標(biāo)準(zhǔn)號(hào):BS EN 61558-2-6-2009
中文標(biāo)準(zhǔn)名稱:小于1100V供電電壓用變壓器、電抗器、供電機(jī)組及類似設(shè)備的安全性.安全隔離變壓器及含有安全隔離變壓器的供電機(jī)組用試驗(yàn)及詳細(xì)要求
英文標(biāo)準(zhǔn)名稱:Safety of transformers, reactors, power supply units and similar products for supply voltages up to 1100 V. Particular requirements and tests for safety isolating transformers and power supply units incorporating safety isolating transformers
標(biāo)準(zhǔn)類型:K41
發(fā)布日期:2010/1/31 12:00:00
實(shí)施日期:2010/1/31 12:00:00
中國(guó)標(biāo)準(zhǔn)分類號(hào):K41
國(guó)際標(biāo)準(zhǔn)分類號(hào):29.180
引用標(biāo)準(zhǔn):IEC 61558-1-2005
適用范圍:Replacement:This part of IEC 61558 deals with the safety of safety isolating transformers for generalapplications and power supply units incorporating safety isolating transformers for general applications. Transformers incorporating electronic circuits are also covered by this standard.NOTE 1 Safety includes electrical, thermal and mechanical aspects.Unless otherwise specified, from here onward, the term transformer covers safety isolating transformers for general applications and power supply units incorporating safety isolating transformers for general applications.NOTE 2 For power supply units (linear) this part is applicable. For switch mode power supply units, IEC 61558-2-16 is applicable together with this part.This part is applicable to stationary or portable, single-phase or polyphase, air-cooled(natural or forced) independent or associated dry- type transformers. The windings may beencapsulated or non-encapsulated.The rated supply voltage does not exceed 1 100 V a.c., and the rated supply frequencyand the internal operating frequencies do not exceed 500 Hz.The rated output does not exceed:– 10 kVA for single-phase transformers;– 16 kVA for polyphase transformers.This part is applicable to transformers without limitation of the rated output subject to anagreement between the purchaser and the manufacturer.NOTE 3 Transformers intended to supply distribution networks are not included in the scope.The no-load output voltage or the rated output voltage does not exceed 50 V a.c. or 120 Vripple-free d.c.This part is not applicable to external circuits and their components intended to be connectedto the input terminals and output terminals of the transformers.Transformers covered by this part are used in applications where double or reinforced insulation between circuits is required by the installation rules or by the end product standard.
相關(guān)標(biāo)準(zhǔn)
百檢網(wǎng)專注于為第三方檢測(cè)機(jī)構(gòu)以及中小微企業(yè)搭建互聯(lián)網(wǎng)+檢測(cè)電商服務(wù)平臺(tái),是一個(gè)創(chuàng)新模式的檢驗(yàn)檢測(cè)服務(wù)網(wǎng)站。百檢網(wǎng)致力于為企業(yè)提供便捷、高效的檢測(cè)服務(wù),簡(jiǎn)化檢測(cè)流程,提升檢測(cè)服務(wù)效率,利用互聯(lián)網(wǎng)+檢測(cè)電商,為客戶提供多樣化選擇,從根本上降低檢測(cè)成本提升時(shí)間效率,打破行業(yè)壁壘,打造出行業(yè)創(chuàng)新的檢測(cè)平臺(tái)。
百檢能給您帶來(lái)哪些改變?
1、檢測(cè)行業(yè)全覆蓋,滿足不同的檢測(cè);
2、實(shí)驗(yàn)室全覆蓋,就近分配本地化檢測(cè);
3、工程師一對(duì)一服務(wù),讓檢測(cè)更精準(zhǔn);
4、免費(fèi)初檢,初檢不收取檢測(cè)費(fèi)用;
5、自助下單 快遞免費(fèi)上門取樣;
6、周期短,費(fèi)用低,服務(wù)周到;
7、擁有CMA、CNAS、CAL等權(quán)威資質(zhì);
8、檢測(cè)報(bào)告權(quán)威有效、中國(guó)通用;