標(biāo)準(zhǔn)號(hào):BS EN 61558-2-1-2007
中文標(biāo)準(zhǔn)名稱:電源變壓器、供電設(shè)備、反應(yīng)器和類似產(chǎn)品的安全性.通用分離變壓器和有分離變壓器的供電設(shè)備的詳細(xì)要求和試驗(yàn)
英文標(biāo)準(zhǔn)名稱:Safety of power transformers, power supplies, reactors and similar products - Particular requirements and tests for separating transformers and power supplies incorporating separating transformers for general applications
標(biāo)準(zhǔn)類型:K41
發(fā)布日期:2007/5/31 12:00:00
實(shí)施日期:2007/5/31 12:00:00
中國(guó)標(biāo)準(zhǔn)分類號(hào):K41
國(guó)際標(biāo)準(zhǔn)分類號(hào):29.180
引用標(biāo)準(zhǔn):IEC 60076-11
適用范圍:Replacement:This part of IEC 61558 deals with safety aspects of separating transformers and powersupplies incorporating separating transformers such as electrical, thermal and mechanicalsafety.This Part 2-1 is applicable to separating transformers and power supplies incorporatingboth separating transformers and electronic circuits. This Part 2-1 is not applicable toexternal circuits and their components intended to be connected to the input terminals, outputterminals or socket-outlets of the transformers and power supplies.This Part 2-1 does not apply to transformers covered by IEC 60076-11.This Part 2-1 applies to stationary or portable, single-phase or polyphase, air-cooled(natural or forced) independent and associated separating transformers and powersupplies, having a rated supply voltage not exceeding 1 000 V a.c., a rated supply andinternal operating frequency not exceeding 500 Hz.The rated output does not exceed:– 1 kVA for single-phase separating transformers and single-phase power suppliesincorporating separating transformers;– 5 kVA for poly-phase separating transformers and poly-phase power suppliesincorporating separating transformers.This Part 2-1 is applicable to separating transformers and power supplies incorporatingseparating transformers without limitation of the rated output subject to an agreementbetween the purchaser and the manufacturer.This Part 2-1 is applicable to dry-type transformers. The windings may be encapsulated ornon-encapsulated.The no-load output voltage or the rated output voltage does not exceed 1 000 V a.c. or1 415 V ripple-free d.c. For independent separating transformers and independent powersupplies, the no-load output voltage and / or the rated output voltage is not less than 50V a.c., or 120 V ripple-free d.c.Separating transformers covered by this Part 2-1 are used only in applications wheredouble or reinforced insulation between circuits is not required by the installation rules orby the end product standard.NOTE 1 Normally, the separating transformers and power supplies incorporating separating transformersare intended to be used with equipment to provide voltages different from the supply voltage for the functionalrequirements of the equipment. The protection against electric shock may be provided (or completed) by otherfeatures of the equipment, such as the body. Parts of output circuits may be connected to the input circuits orto protective earth.This Part 2-1 is applicable to separating transformers and power supplies incorporatingseparating transformers associated with specific equipment, to the extent decided upon bythe relevant IEC technical committees.NOTE 2 Attention is drawn to the following:– for separating transformers and power supplies incorporating separating transformers intended to be usedin vehicles, on board ships, and aircraft, additional requirements (from other applicable standards, nationalrules, etc.) may be necessary;– measures to protect the enclosure and the components inside the enclosure against external influences suchas fungus, vermin , termites, solar-radiation, and icing should also be considered;– the different conditions for transportation, storage, and operation of the separating transformers and powersupplies incorporating separating transformers should also be considered;– additional requirements in accordance with other appropriate standards and national rules may be applicable toseparating transformers and power supplies incorporating separating transformers intended for use inspecial environments, such as tropical environment.NOTE 3 Future technological development of separating transformers and power supplies incorporatingseparating transformers may necessitate a need to increase the upper limit of the frequencies, until then thisPart 2-1 may be used as a guidance document.
相關(guān)標(biāo)準(zhǔn)
《GB/T11032-20208.14,10.8.14》交流無(wú)間隙金屬氧化物避雷器
《GB/T11032-20208.13,10.8.13,11.8.13》交流無(wú)間隙金屬氧化物避雷器
《GB/T11032-20208.14,10.8.14》交流無(wú)間隙金屬氧化物避雷器
《GB/T11032-20208.21,10.8.21,11.8.21》交流無(wú)間隙金屬氧化物避雷器
《GB/T11032-202011.8.27》交流無(wú)間隙金屬氧化物避雷器
《GB/T11032-20208.11,10.8.11》交流無(wú)間隙金屬氧化物避雷器
《GB/T11032-20208.2,10.8.2,11.8.2,13.8.2》交流無(wú)間隙金屬氧化物避雷器
《GB/T11032-20208.12,10.8.12》交流無(wú)間隙金屬氧化物避雷器
《GB/T11032-20208.10,10.8.10,11.8.10》交流無(wú)間隙金屬氧化物避雷器
《GB/T11032-202011.8.28》交流無(wú)間隙金屬氧化物避雷器
百檢網(wǎng)專注于為第三方檢測(cè)機(jī)構(gòu)以及中小微企業(yè)搭建互聯(lián)網(wǎng)+檢測(cè)電商服務(wù)平臺(tái),是一個(gè)創(chuàng)新模式的檢驗(yàn)檢測(cè)服務(wù)網(wǎng)站。百檢網(wǎng)致力于為企業(yè)提供便捷、高效的檢測(cè)服務(wù),簡(jiǎn)化檢測(cè)流程,提升檢測(cè)服務(wù)效率,利用互聯(lián)網(wǎng)+檢測(cè)電商,為客戶提供多樣化選擇,從根本上降低檢測(cè)成本提升時(shí)間效率,打破行業(yè)壁壘,打造出行業(yè)創(chuàng)新的檢測(cè)平臺(tái)。
百檢能給您帶來(lái)哪些改變?
1、檢測(cè)行業(yè)全覆蓋,滿足不同的檢測(cè);
2、實(shí)驗(yàn)室全覆蓋,就近分配本地化檢測(cè);
3、工程師一對(duì)一服務(wù),讓檢測(cè)更精準(zhǔn);
4、免費(fèi)初檢,初檢不收取檢測(cè)費(fèi)用;
5、自助下單 快遞免費(fèi)上門取樣;
6、周期短,費(fèi)用低,服務(wù)周到;
7、擁有CMA、CNAS、CAL等權(quán)威資質(zhì);
8、檢測(cè)報(bào)告權(quán)威有效、中國(guó)通用;