標(biāo)準(zhǔn)號:BS DD CEN/TS 14793-2005
中文標(biāo)準(zhǔn)名稱:固定源排放.交替法與參照法比較的實(shí)驗(yàn)室內(nèi)驗(yàn)證過程
英文標(biāo)準(zhǔn)名稱:Stationary source emission — Intralaboratory validation procedure for an alternative method compared to a reference method
標(biāo)準(zhǔn)類型:X04
發(fā)布日期:2006/1/19 12:00:00
實(shí)施日期:2006/1/19 12:00:00
中國標(biāo)準(zhǔn)分類號:X04
國際標(biāo)準(zhǔn)分類號:13.040.40
引用標(biāo)準(zhǔn):ENV 13005;EN ISO 14956;ISO 5725-2
適用范圍:The purpose of this Technical Specification is to specify a validation procedure to show if an Alternative Method (AM) can be used as an alternative to the Standard Reference Method (SRM), both implemented to determine the same measurand. This document has been drawn up for laboratories working in air pollution measurements (and consequently examples taken from this sector are included in the appendices).In particular, this Technical Specification provides the statistical tools and different criteria to evaluate the alternative method; this does not release the person responsible for this validation from bearing technical and analytical judgement on the evaluation of the different criteria.Three steps are described in the validation procedure:? description of the AM and setting of the field of equivalence (range and type of gas matrix);? determination of the performance characteristics of the AM and calculation of the overall uncertainty where appropriate and check of compliance of the maximum overall uncertainty allowed for the SRM;? check of repeatability and lack of systematic deviation of the AM in the field in comparison with the SRM for the type of matrix defined in the field of equivalence.NOTE Some parts of the second step of the validation of the alternative method should be performed by a recognised test-house.If the AM fulfils the requirement of the procedure, then the laboratory that carried out the whole validation process is allowed to use it as a SRM in the field application where the equivalence has been demonstrated.However, if the validation process involves at least 4 different accredited laboratories performing simultaneously parallel measurements in the field, and if the AM passes with success all the tests of the procedure, then this method could be proposed to CEN, who can decide to consider this AM as a new reference method (ARM).The use of this procedure implies that a reference method has been defined by the regulator or in a contract and has been validated.This Technical Specification only considers the case of linear quantitative methods.
相關(guān)標(biāo)準(zhǔn)
《GB 7493-1987》水質(zhì) 亞硝酸鹽氮的測定 分光光度法 GB 7493-1987
《3.1.7(2》《水和廢水監(jiān)測分析方法》(第四版 )國家環(huán)境保護(hù)總局2002年103-105℃烘干的可濾殘?jiān)?3.1.7(2)
《3.1.7(3》《水和廢水監(jiān)測分析方法》(第四版 )國家環(huán)境保護(hù)總局2002年180℃烘干的可濾殘?jiān)?3.1.7(3)
《GB 7484-1987》水質(zhì) 氟化物的測定 離子選擇電極法 GB 7484-1987
《3.2.5(1》《水和廢水監(jiān)測分析方法》(第四版 )國家環(huán)境保護(hù)總局2002年 碘量法 3.2.5(1)
《3.1.9(2》《水和廢水監(jiān)測分析方法》(第四版)國家環(huán)境保護(hù)總局2002年實(shí)驗(yàn)室電導(dǎo)率儀法 3.1.9(2)
《HJ/T 342-2007》水質(zhì) 硫酸鹽的測定 鉻酸鋇分光光度法 (試行) HJ/T 342-2007
《GB 11903-1989》水質(zhì) 色度的測定 GB 11903-1989 4鉑鈷比色法
《3.1.5(2》《水和廢水監(jiān)測分析方法》(第四版)國家環(huán)境保護(hù)總局2002年 塞氏盤法 3.1.5(2)
《3.1.11(1》《水和廢水監(jiān)測分析方法》(第四版 增補(bǔ)版)國家環(huán)境保護(hù)總局2002年 酸堿指示劑滴定法 3.1.11(1)
百檢網(wǎng)專注于為第三方檢測機(jī)構(gòu)以及中小微企業(yè)搭建互聯(lián)網(wǎng)+檢測電商服務(wù)平臺,是一個創(chuàng)新模式的檢驗(yàn)檢測服務(wù)網(wǎng)站。百檢網(wǎng)致力于為企業(yè)提供便捷、高效的檢測服務(wù),簡化檢測流程,提升檢測服務(wù)效率,利用互聯(lián)網(wǎng)+檢測電商,為客戶提供多樣化選擇,從根本上降低檢測成本提升時間效率,打破行業(yè)壁壘,打造出行業(yè)創(chuàng)新的檢測平臺。
百檢能給您帶來哪些改變?
1、檢測行業(yè)全覆蓋,滿足不同的檢測;
2、實(shí)驗(yàn)室全覆蓋,就近分配本地化檢測;
3、工程師一對一服務(wù),讓檢測更精準(zhǔn);
4、免費(fèi)初檢,初檢不收取檢測費(fèi)用;
5、自助下單 快遞免費(fèi)上門取樣;
6、周期短,費(fèi)用低,服務(wù)周到;
7、擁有CMA、CNAS、CAL等權(quán)威資質(zhì);
8、檢測報(bào)告權(quán)威有效、中國通用;